  1. 目录
  2. 6千伏电缆
  3. VBV 6kV

VBV 6kV

1 -  Sheath
2 - Armour of galvanized steel strips
3 - Inner sheath
4 - Polymer taping
5 - Shield of copper wires or copper tape
6 - Conducting tape
7 - Separation layer
8 - Insulation
9 - Conductor

DESCRIPTION

Power cable with insulated copper conductors, with a copper shield and armour made of galvanized steel strips in a sheath and inner sheath of PVC compound.

CONDUCTOR ACCORDING TO GOST 22483

1. Copper, multi-wire, round-shaped, Class 2. Number of conductors: 3, cross-section: 25-50 sq. mm
2. Copper, multi-wire, sector-shaped, Class 2. Number of conductors: 3, cross-section: 70-240 sq. mm

INSULATION, INNER SHEATH AND SHEATH

VBV

Insulation, inner sheath and sheath of polyvinyl chloride compound with armour made of galvanized steel strips.

VBVng(A)

Insulation and inner sheath of polyvinyl chloride compound, outer sheath of low-combustible polyvinyl chloride compound with armour made of galvanized steel strips.

VBVng(A)-LS

Insulation, inner sheath and outer sheath of polyvinyl chloride compound with low fire danger, reduced smoke and gas emission and armour made of galvanized steel strips.

VBVng(A)-HL

Insulation and inner sheath of polyvinyl chloride compound, outer sheath of low-combustible polyvinyl chloride compound with increased cold resistance and armour made of galvanized steel strips.

VBVng(A)-LS-HL

Insulation, inner sheath and outer sheath of polyvinyl chloride compound with low fire danger and reduced smoke and gas emission.


APPLICATIONS

The cables are designed for transmission and distribution of electric power in stationary electrical installations with a rated alternating voltage of 0.66 and 1 kV of a rated frequency of 50Hz. The cables are designed for laying single cable lines in cable structures and premises. When laying such cables in groups, the use of fire protection means is mandatory.
Cables with the -ng(A) and -ng(A)-HL indices are designed for group laying in cable structures of outdoor (open) electrical installations (overhead cable tray systems, cableways). Cables with the -ng(A)-LS and -ng(A)-LS-HL indices are designed for group laying of cable lines in cable structures and premises of indoor (closed) electrical installations, including at nuclear power facilities. For electrical wiring in residential and public buildings.